Controls for Heating Systems |
|
¡@ |
 |
¡@ |
Air /
Gas Ratio Regulators |
|
- |
Maintains Constant gas/air ratio to optimize combustion |
|
- |
internal low fire by-pass available |
|
- |
Wide
regulating range |
|
- |
For
continuous high/low, and pre-heated air applications |
|
- |
Inlet
pressures up to 3 psig |
|
- |
Outlet pressures to 48 inch WC |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Solenoid Valves for Gas |
|
- |
For
natural gas, LPG, and air applications |
|
- |
Valve
types include solenoid operated shutoff valves |
|
- |
Closed Position indicator, Visual indicator and Over
travel Switch options available |
|
- |
Sizes
from 1/8 inch to 4 inches |
|
- |
AC
power supply - DC coil systems |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Pressure Reducing Regulators |
|
- |
Low
and medium pressure regulators |
|
- |
High
regulating precision with various types of gaseous media |
|
- |
Inlet
pressure up to 60 psig |
|
- |
Springs available for outlet pressure adjustments |
|
- |
Outlet pressure adjustment up to 100 inch WC |
|
- |
Sizes
from 1/2 inch to 4 inches |
|
- |
Outlet pressure cut off |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Control valves for Air |
|
- |
Ideal
for setting flow rates of air |
|
- |
Low
leakage rates and pressure losses |
|
- |
Some
models available with position indicator |
|
- |
Motors |
|
- |
Actuated via three step, continuous, or two-point
signal |
|
- |
Infinitely adjustable switching cams standard for
precise setting |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Ignition Transformers |
|
- |
For
ignition of gas burners |
|
- |
Compact dimensions for cabinet or well mounting |
|
- |
Ignition and burner monitoring with common electrode |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Pressure Switches for Gas and Air |
|
- |
Available for sensing gas pressure or air pressure |
|
- |
Sensing range of 0.2 inch WC to 7 psi for gas |
|
- |
AC
power supply - DC coil systems |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Valve
Proving Controls |
|
- |
Checks both shut-off valves for leakage |
|
- |
Prevents burner from starting if leak is detected |
|
- |
Testing before or after burner run |
|
- |
Separate pressure switch not required |
|
- |
Extremely safe due to self-monitoring electronics |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Ball
valves, Filters, Orifice Assembly, Pressure Gages |
|
- |
Ball
valves with maximum operating pressures to 60 psi |
|
- |
Filters with maximum inlet pressures from 15 psi to 60
psi for gas and air |
|
- |
Orifice plate assemblies allow precise flow of natural
gas and air |
|
- |
Pressure gage assemblies with push to test cock |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Turbine Meters |
|
- |
For
measurement of flow and volume (to 3500 CFH) |
|
- |
Analog or LCD display head |
|
- |
Turndown range up to 20:1 |
|
- |
Compact design with universal mounting position |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
Burner Control - Safeguards, Detectors, Sensors |
|
- |
Unites functionally interrelated components such as
ignition transformer, gas solenoid valve, and flame
supervision device |
|
- |
Flame
detection with flame rod or UV detector |
|
- |
Options for restart or immediate fault lock-out
following flame failure |
|
¡@ |
¡@ |
¡@ |
Burners
for Gas |
|
¡@ |
 |
¡@ |
BIO,
BIOA, ZIO Burners |
|
- |
Burner with metel firing tube up to 1800
¢K |
|
- |
Optimized combustion efficiency |
|
- |
Burner tube lengths in 4 inch increments (4 inch to 48
inch) |
|
- |
Can
be fired with refractory or heat resistant alloy tube |
|
- |
Capacity range up to 3,400,000 BTH/Hr |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
BIC
Burners |
|
- |
Burner with silicon carbide firing tube (TSC) |
|
- |
Suitable for furnaces and kilns |
|
- |
Capacity range up to 1,200,000 BTU/Hr |
|
- |
Can
be installed in fiber or brick linings |
|
- |
Burner tubes available in various length and discharge
diameters |
|
¡@ |
¡@ |
¡@ |
¡@ |
|
¡@ |
 |
¡@ |
BICR
Burners |
|
- |
For
direct and indirect operation |
|
- |
Unique low cost design |
|
- |
Silicon carbide recuperator |
|
- |
Application for industrial heat treat furnace using
single ended P-tubes |
|
- |
Various recuperator lengths available |